User's Manual

Lucent Technologies Proprietary
See notice on first page
16-10
401-660-100 Issue 11 August 2000
Corrective Maintenance using Status Display Pages
The conditional remove maintenance action changes the state of a
maintenance unit from active or standby to out-of-service. It schedules an
event or process to place the specified maintenance unit to out-of-service
assuming that by doing so does not cause calls to be dropped or service
denied to a user.
NOTE:
You can use the
2131 - Cell Equipment Status
page to unconditionally
remove Cell Site units from service by typing,
ucl
at the end of the input you
type at the
CMD<
prompt. Be aware that unconditional remove requests
may be service affecting.
2131 - Procedure to Remove a Cell Site Unit
1. Select
ECP Control & Display
from the
AUTOPLEX(R) System
1000 ECP Access
menu.
2. Open the
2131 - Cell Equipment Status
page by entering command
2131,
c (where c is the Cell Site number).
3. At the
CMD<
line,
To remove the...
enter...
CSC (Cell Site controller)
20
followed by the CSC number (0-1) and press
RETURN
.
DL (data links)
21
followed by the data link number (0-1) and
press
RETURN
.
CAT or SCT (clock
and tone) units
22
followed by the CAT (or SCT) number (0-5)
and press
RETURN
.
RTU (AMPS radio test unit)
250
and press
RETURN
.
TRTU (TDMA radio test unit)
251
and press
RETURN
.
CRTU (CDMA radio test unit)
252
and press
RETURN
.
NOTE:
This ends the procedure for using the
2131
page to conditionally remove
Cell Site units from service
After the system processes the command, an output message report scrolls up
from the bottom of the window. In addition, the output message report is sent to a
log file. The following is an example of a successful output message report.