User's Manual

Lucent Technologies Proprietary
See notice on first page
401-660-100 Issue 11 August 2000
19-9
Cell Site Hardware LED Descriptions
CRTUi
x Red Lighted during the self-test initiated
upon powerup or after a reset and
goes off after successful comple-
tion of the self-test; lighted during
normal operation if the CRTUi has a
board error or is insane.
Yellow Lighted during NVM update.
Green Lighted when a CDMA functional
test is executing.
RFTG
x Red Upon powerup, lights for approxi-
mately 4 to 6 minutes while oscilla-
tor is warming up and then goes off;
during normal operation, lighted red
LED indicates an oscillator failure
or, for a crystal oscillator, that the
oscillator may be in an unlocked
state.
Yellow For a rubidium-crystal oscillator
combination, indicates that the
backup crystal oscillator is
phase-locked to the rubidium oscil-
lator; for a two-rubidium oscillator
combination, indicates that the
backup rubidium oscillator is ready
for operation.
Green Indicates that the oscillator is active.
PCU
(430AA) +5
Vdc
x Red Indicates one of the following
alarms: low input voltage shutdown
alarm (
non-latched shutdown),
high
output voltage shutdown alarm
(
latched shutdown),
over-current shut-
down alarm (
latched shutdown)
or low
output voltage alarm (
no shutdown).
Green Indicates the presence of input volt-
age (+24 Vdc nominal)
Table 19-1. Cell Site Hardware Status Indicators (Contd)
Hardware
Unit
Hardware Type
LED DescriptionGen AMPS TDMA CDMA