Corrective Maintenance using Status Display Pages
2131 - Generating
Cell Equipment
Status Reports
You can use the
2131 - Cell Equipment Status
page (See Figure 16-2) to
generate status output message reports on Cell Sites and Cell Site units.
2131 - Procedure to Generate Cell Equipment Status Reports
1. Select
ECP Control & Display
from the
AUTOPLEX(R) System
1000 ECP Access
menu.
2. Open the
2131 - Cell Equipment Status
page by entering command
2131,
c (where c is the Cell Site number).
3. At the
CMD<
line,
For status on a...
enter...
CSC (Cell Site controller)
40
followed by the CSC number (0-1) and press
RETURN
.
DL (data links)
41
followed by the data link number (0-1)
and press
RETURN
.
CAT or SCT (clock and
tone) units
42
followed by the CAT (or SCT) number
(0-5) and press
RETURN
.
RG (reference generator)
43
followed by the RG number (0-1) and
press
RETURN
.
RCG (receiver calibration
generator)
440
and press
RETURN
.
RTU (AMPS radio test unit)
450
and press
RETURN
.
TRTU (TDMA radio test unit)
451
and press
RETURN
.
CRTU (CDMA radio test unit)
452
and press
RETURN
.
Cell Site
490
and press
RETURN
.
MRAQ
491
and press
RETURN
.
NOTE:
This ends the procedure for using the
2131
page to generate status output
message reports on Cell Sites and Cell Site units.