User's Manual

Lucent Technologies Proprietary
See notice on first page
21-8
401-660-100 Issue 11 August 2000
CDMA Maintenance
Cell Equipage Common Form
The
ceqcom2
form contains information concerning Cell Site equipment
configuration, status, and maintenance-related parameters for an individual Series
II cell. The values on the
ceqcom2
form take precedence over the values on the
ecp
form.
The following new fields have been added to the Radio Test Unit screen of the
ceqcom2
form:
CDMA RTU - Status
Used to equip a CRTU at a Series II cell.
The allowed values for the CDMA RTU (CRTU) status field are
unequipped, equipped, and growth. The default value is unequipped. When
equipped, the CRTUi slot location is fixed at frame 0, shelf 0, slot 15.
Functional Test Intervals:
CDMA Overhead Channels (min)
CDMA Traffic Path (min)
The interval value for the routine (scheduled) overhead channel functional test
and the interval value for the routine (scheduled) traffic path functional test can be
set to any value within the range 1 - 1440 minutes in increments of 1 minute.
There are no default interval values on the
ceqcom2
form.
Value 1439 has special meaning. Setting the interval value to 1439 for
CDMA
Overhead Channels (min)
disables the execution of routine CDMA overhead
channel functional tests and prevents the Cell Site from reporting an off-normal
alarm to the ECP. Likewise, setting the interval value to 1439 for
CDMA Traffic
Path (min)
disables the execution of routine CDMA traffic path functional tests
and prevents the Cell Site from reporting an off-normal alarm to the ECP.
An interval value specified here will override the interval value (including 1439)
specified on the
ecp
form. However, when an interval value is null (no entry) on
the
ceqcom2
form, the interval value on the
ecp
form is used by the cell.
Subscriber and
Feature
Information Form
The
sub
form contains information for the mobile subscriber, including any custom
calling features the subscriber may have.
The following new values have been added to the Mobile Directory Number Type
field of the
sub
form:
y
for CDMA RTU (CRTU) test mode mobile
b
for CDMA test mode mobile.
There are two types of CDMA MOST calls: those that are originated by the CRTU,
and those that are originated by any other IS-95 compliant test mobile. Both the
ECP and RCC can distinguish between the two types of MOST calls because