User's Manual

Lucent Technologies Proprietary
See notice on first page
22-4
401-660-100 Issue 11 August 2000
Linear Amplifier Circuit (LAC) Maintenance
LAC Alarm
Summary:
LACSUM
Before the start of the maintenance period, log-on to the ECP and print a copy of
the LACSUM report
*
. This report provides a summary of the day's LAC alarms for
each cell site controlled by the ECP.
After logging on, type in the following commands:
NOTE:
As an aid in troubleshooting, a copy of the LACSUM report should be taken
to the cell site when performing maintenance.
The LACSUM report, which is updated hourly, records the number of LAC alarms,
by category, for up to 24 hours beginning at 6AM. At 6AM the following day, the 24
hour summary is saved for reference as LACSUM.Ext, where Ext denotes the day
of the week the file was saved. (LACSUM.Fri contains alarms from 6AM Thursday
to 6AM Friday.)
A sample LACSUM report listing alarm totals by cell and LAC number under the
following categories is shown in Table 22-1:
* If the
LACSUM
file is not found in the
LACMON
directory on the ECP, contact the system administrator or call the
AT&T CTSO Hotline at 1-800-225-4672.
cd /user/pecc/LAC-
MON
to change to the
LACMON
directory
cat LACSUM
to list the
LACSUM
file