User's Manual

Lucent Technologies Proprietary
See notice on first page
22-88
401-660-100 Issue 11 August 2000
12. Remove the fan from its sheet metal mounting plate. Save the screws,
finger guards, and plate. Take note of the positioning of fans and finger
guards.
13. Discard old fan and replace with new fan.
14. Fasten the new fan and finger guards onto the mounting plate.
NOTE:
Air should flow to the left. See marking on fan label for air flow direction.
15. Splice cabling by color (red to red, black to black, blue to blue) using heat
gun.