Corrective Maintenance using Status Display Pages
Inhibit automatic execution
of cell routine diagnostics
600,
followed by the cell number
(1-222) and press
RETURN
.
Allow automatic execution
of cell routine diagnostics
700,
followed by the cell number
(1-222) and press
RETURN
.
!
CAUTION:
This option may permit faulty operational or test equipment to remain in
service.
NOTE:
This ends the procedure for using the
2138
page to remove, restore,
diagnose, or generate a status output message report for a CCC.
Result:
After the system processes the command, an output message report scrolls up
from the bottom of the window. In addition, the output message report is sent to a
log file. The following is an example of a successful output message report.
Example:
DGN:CELL 8 CCC 7 COMPLETED ALL TESTS PASSED
References:
See the following documents for additional information:
AUTOPLEX Cellular Telecommunications Systems System 1000 Output
Messages (401-610-057)
2139 - Cell CCC
CCU Status
Display Page
The
2139 - Cell CCC CCU Status
page (See Figure 16-11, and Table 16-11)
displays the summary status and maintenance commands for the following CDMA
feature components associated with a user-specified CDMA cluster controller
(CCC):
CDMA channel unit (CCU)
Channel element (CE)
Special purpose channel
Packet pipe (PP) trunk group member.