User's Manual

Lucent Technologies Proprietary
See notice on first page
17-8
401-660-100 Issue 11 August 2000
Corrective Maintenance using ECP Craft Interface
NOTE:
See the AUTOPLEX Cellular Telecommunications Systems System 1000
Input Messages (401-610-055) for more information about message
parameters.
Result:
After the system processes the command, an output message report scrolls up
from the bottom of the window. In addition, the output message report is sent to a
log file. The following is an example of a successful output message report.
Example:
RST:CELL 1 SU 7, COMPLETED
References:
See the following documents for additional information:
AUTOPLEX Cellular Telecommunications Systems System 1000 Output
Messages (401-610-057)
AUTOPLEX System 1000 Virtual System Output Message Routing
Optional Feature (401-612-021)
Feature documents are contained in AUTOPLEX Cellular
Telecommunications Systems System 1000 Optional Features (401-900-
004)
Diagnosing Cell
Site Units
You can run diagnostics on specific Cell Site units.
The diagnose maintenance action can be applied to a unit in the out-of-service or
growth state, to a redundant unit in the standby state, or to a redundant unit in the
active state. In the latter case, MRA initiates a switch before executing the
diagnose request.
For redundant units, if the targeted unit is in the active state but the mate is out-of-
service, the diagnose aborts with no action taken.
In addition, the diagnose maintenance action can be applied to a CCC, CCU, or
CRTU in the active state. The first step in a diagnose maintenance action for an
active CCC, CCU, or CRTU is the automatic execution of a conditional remove.
Procedure to Run Cell Site Unit Diagnostics
1. Select
ECP Craft Shell
from the
AUTOPLEX(R) System 1000 ECP
Access
menu.