Corrective Maintenance using ECP Craft Interface
Example:
SW:SPECTRUM SWAP CDMA ON, FINISHED
ALL CELLS FINISHED SWAP
References:
See the following documents for additional information:
AUTOPLEX Cellular Telecommunications Systems System 1000 Output
Messages (401-610-057)
AUTOPLEX Cellular Telecommunications Systems System 1000 CDMA
Spectrum Swap (401-613-001).
Running Cell Site
Audits
You can request audits on one or more Cell Sites.
Procedure to Audit Cell Sites
1. Select
ECP Craft Shell
from the
AUTOPLEX(R) System 1000 ECP
Access
menu.
2. When the connection is established, enter the following command:
AUD:CELL a,NAME b [ CLASS c]
where
a. A single Cell Site, a range or cells (maximum 32), or a list of
cells.
b. Indicates the audit you want to run.
c. Indicates output message class override.
NOTE:
See the AUTOPLEX Cellular Telecommunications Systems System 1000
Input Messages (401-610-055) for more information about message
parameters.
Result:
After the system processes the command, an output message report scrolls up
from the bottom of the window. In addition, the output message report is sent to a
log file. The following is an example a of successful output message report.
Example: