User's Manual

Lucent Technologies Proprietary
See notice on first page
401-660-100 Issue 11 August 2000
17-17
Corrective Maintenance using ECP Craft Interface
AUD:CELL 10 NAME ARCCC,COMPLETED, ERROR COUNT 4
References:
See the following documents for additional information:
AUTOPLEX Cellular Telecommunications Systems System 1000 Output
Messages (401-610-057)
Cell Site Audits (401-610-078)
AUTOPLEX System 1000 Virtual System Output Message Routing
Optional Feature (401-612-021)
NOTE:
Feature documents are contained in AUTOPLEX Cellular
Telecommunications Systems System 1000 Optional Features (401-900-
004).
Diagnosing Cell
Site Data Links
You can diagnose Cell Site data links, and, using the loopback option, test the
associated transmission facility.
Procedure to Diagnose Cell Site Data Links
1. Select
ECP Control & Display
from the
AUTOPLEX(R) System
1000 ECP Access
menu.
2. Open the
2131 - Cell Equipment Status
page by entering command
2131,
c (where c is the Cell Site number).
NOTE:
For a customized restore using a manually entered command, skip Step 3
and go to Step 4.
3. At the
CMD<
line, enter
51,
followed by the cell number (1-222) and press
RETURN
.
NOTE:
This ends the procedure for using the status display page command. See
Result and Example.
4. Press the
F3
(
CMD/MSG
) key to position the cursor at the bottom of the
page and enter the following command:
DGN:CELL a,DL b;c [;ERR][,RPT d][,UCL][CLASS e]