17-18
401-660-100 Issue 11 August 2000
Corrective Maintenance using ECP Craft Interface
where
a. Indicates the Cell Site number.
b. Data link number.
c. Indicates the diagnostic test type.
ERR
Dumps the protocol error registers at the conclusion of the
loopback test.
d. Indicates the number of times you want the test repeated.
UCL
Indicates an unconditional execution of the diagnostic with no
early termination and printing all failures (conditional stops
on first failure).
e. Indicates message class override.
NOTE:
See the AUTOPLEX Cellular Telecommunications Systems System 1000
Input Messages (401-610-055) for more information about message
parameters.
Result:
After the system processes the command, an output message report scrolls up
from the bottom of the window. In addition, the output message report is sent to a
log file. The following is an example of a successful output message report.
Example:
DGN:CELL 1 DL 0, COMPLETED, ALL TESTS PASSED
References:
See the following documents for additional information:
AUTOPLEX Cellular Telecommunications Systems System 1000 Output
Messages (401-610-057)
AUTOPLEX System 1000 Virtual System Output Message Routing
Optional Feature (401-612-021)
NOTE:
Feature documents are contained in AUTOPLEX Cellular
Telecommunications Systems System 1000 Optional Features (401-900-
004).