User's Manual

Lucent Technologies Proprietary
See notice on first page
401-660-100 Issue 11 August 2000
17-21
Corrective Maintenance using ECP Craft Interface
DGN:CELL 1 SG 0 ANT 6, COMPLETED
References:
See the following documents for additional information:
AUTOPLEX Cellular Telecommunications Systems System 1000 Output
Messages (401-610-057)
Stopping
Diagnostics on
Cell Site Trunks
Associated with a
Server Group and
Antenna Face
You can stop Cell Site trunk diagnostics associated with a specific cell, server
group, and antenna face.
Procedure to Stop Diagnostics on a Cell Site Trunk Server Group and
Antenna Face
1. Select
ECP Craft Shell
from the
AUTOPLEX(R) System 1000 ECP
Access
menu.
2. When the connection is established, enter the following command:
STOP:DGN;CELL a,SG b,ANT c
where
a. Indicates the Cell Site number.
b. Indicates the server group number.
c. Indicates the antenna face number.
NOTE:
See the AUTOPLEX Cellular Telecommunications Systems System 1000
Input Messages (401-610-055) for more information about message
parameters.
Result:
After the system processes the command, an output message report scrolls up
from the bottom of the window. In addition, the output message report is sent to a
log file. The following is an example of a successful output message report.
Example:
STOP:DGN;CELL 1 SG 0 ANT 6 COMPLETED