Cable connections in the Modular Cell 4.0B cabinets
Connection of user alarms to the EFIM punchdown blocks in the
.............................................................................................................................................................................................................................................................
Modular Cell 4.0B primary cabinet
Overview
This procedure module provides instructions for connecting of the
external user alarm cables in all Modular Cell 4.0B primary cabinets, as
well as the connection of dual band power user alarm cables in
Modular Cell 4.0B primary cabinets with integrated power.
Punch down the external
user alarms cables on the
EFIM in Modular Cell 4.0B
cabinets
The external user alarms will be connected to the punchdown terminals
on the EFIM inside of the Modular Cell 4.0B primary cabinet. External
user alarms are attached only at the primary cabinet. The EFIM is
accessible from the front of the cabinet, behind a slide-out tray (EFIT -
facilities interface tray). Refer to the figure on Page 3-53. Use the
following procedure to connect the user alarms to the EFIM in a
Modular Cell 4.0B primary cabinet
Important! When performing the next step, note that seven
punchdowns (0 through 6) are factory-wired for internal power
alarms (in cabinets with integrated power), and must not be used
for external user alarms.
.....
......................................................................................................................................
1 Connect the external user alarm wire pairs as follows. Refer to the figure
on Page 3-53, Note 2, and the table on Page 3 - 54. Do not use
punchdowns 0 through 6. Start at pair 7.
If applicable, connect the user alarms to connector J3
punchdowns, pairs 7 through 15 respectively
If applicable, connect additional user alarms to connector J4
punchdowns, pairs 16 through 31 respectively
Important! Note that connector J4 is not shown in detail in the
referenced figure.