Cable connections in the Modular Cell 4.0B cabinets
3- 49
Lucent Technologies – Proprietary
See notice on first page
401-703-454
FOA Draft Issue 1
January, 2006
............................................................................................................................................................................................................................................................
Route and punch down the
dual band cabinet
integrated power alarms on
the EFIM in the Modular
Cell 4.0B primary cabinet, if
applicable
Important! If installing a Modular Cell 4.0B cabinet that does
not have integrated power, skip to Appendix B for customer
supplied power connections. If not installing a dual band cabinet,
proceed to Chapter 4.
The dual band cabinet integrated power alarms will be connected to the
punchdown terminals on the EFIM inside of the Modular Cell 4.0B
primary cabinet. Dual band cabinet integrated power alarms are
attached only at the primary cabinet. The EFIM is accessible from the
front of the cabinet, behind a slide-out tray (EFIT - facilities interface
tray). Refer to the figure on Page 3-53. Use the following procedure to
route and connect the dual band power user alarms to the EFIM in a
Modular Cell 4.0B primary cabinet
................................................................................................................................
............................................
1 Refer to the figure below for an illustration of the dual band cabinet
integrated power alarm cable
WIRE COLOR CODES