User's Manual

3-54
Lucent Technologies – Proprietary
See notice on first page
401-703-454
FOA Draft Issue 1
January, 2006
...........................................................................................................................................................................................................................................................
Cable connections in the Modular Cell 4.0B cabinets
USER ALARM TABLE
Alarm # Wire Color "J" Conn. Terminal Block Pair Block C/C Protector
USER ALARMS 0 THROUGH 6 UTILIZED FOR INTERNAL POWER ALARMS
User 0
Alarm
If installing a
primary cabinet
without
integrated
power,
refer to
Appendix B for
alarm
conn
ections.
from a customer
supplied power
source
J3 + 0 (Top) Blue J9A (0 / 1)
- 0 (Bottom)
User 1
Alarm
J3 + 1 (Top) Orange
- 1 (Bottom)
User 2
Alarm
J3 + 2 (Top) Green J9A (2 / 3)
- 2 (Bottom)
User 3
Alarm
J3 + 3 (Top) Brown
- 3 (Bottom)
User 4
Alarm
J3 + 4 (Top) Blue J9A (4 / 5)
- 4 (Bottom)
User 5
Alarm
J3 + 5 (Top) Orange
- 5 (Bottom)
User 6
Alarm
J3 + 6 (Top) Green
J9A (6 / 7)
Shared
- 6 (Bottom)
START EXTERNAL USER ALARM PUNCHDOWNS HERE
User 7
Alarm
White-Blue J3 + 7 (Top) Brown J9A (6 / 7)
Shared
Blue-White - 7 (Bottom)
User 8
Alarm
White-Orange J3 + 8 (Top)
Blue
J9B (8 / 9)
Orange-White - 8 (Bottom)
User 9
Alarm
White-Green J3 + 9 (Top) Orange
Green-White - 9 (Bottom)
User 10
Alarm
White-Brown J3 + 10 (Top) Green J9B (10 / 11)
Brown-White - 10 (Bottom)
User 11
Alarm
White-Slate J3
+ 11 (Top)
Brown
Slate-White - 11 (Bottom)
User 12
Alarm
Red-Blue J3 + 12 (Top)
Blue
J9B (12 / 13)
Blue-Red - 12 (Bottom)
User 13
Alarm
Red-Orange J3 + 13 (Top) Orange
Orange-Red - 13 (Bottom)
User 14
Alarm
Red-Green J3 + 14 (Top) Green J9B (14 / 15)
Green-Red - 14 (Bottom)
User 15
Alarm
Red-Brown J3 + 15 (Top) Brown