Cable connections in the Modular Cell 4.0B cabinets
................................................................................................................................
............................................
5 Push the braided shield back on the inside insulation as shown.
................................................................................................................................
............................................
6 Cut off the exposed inside insulation.
................................................................................................................................
............................................
7 Twist the T1/E1 and user alarm cable shields at the end of the cables in
preparation for their attachment to a grounding clamp located on the
facilities interface module. Refer to the figure below.
................................................................................................................................
............................................
8 Repeat steps 1 through 7 for each cable.
................................................................................................................................
............................................
9 Quality Check - Verify the following.
1. Check that all cables are firmly held by the seal and is not loose.
2. Using an ohmmeter, check continuity between the frame and the
cable shield at the end of each cable to ensure that it is bonded in
the cord grip seal.