User's Manual

3-40
Lucent Technologies – Proprietary
See notice on first page
401-703-454
FOA Draft Issue 1
January, 2006
...........................................................................................................................................................................................................................................................
Cable connections in the Modular Cell 4.0B cabinets
T1/E1 Line
Assignment
Terminal Block
Pair/ Tip Ring
NOTE 3
"J"
Conn.
Block
C/C
Protector
Location
URC
Position
number
Line __
TX9-T (Top)
J2 Blue
J8A/TX-9 URC,
Position 3
NOTE 2
TX9-R (Bottom)
RX9-T (Top)
Orange
J8B/RX-9
RX9-R (Bottom)
Line __ TX10-T (Top)
J2 Green
J8C/TX-10
TX10-R (Bottom)
RX10-T (Top) Brown J8D/RX-10
RX10-R (Bottom)
Line __ TX5-T (Top)
J2 Blue
J8A/TX-5 URC,
Position 2
NOTE 2
TX5-R (Bottom)
RX5-T (Top)
Orange
J8B/RX-5
RX5-R (Bottom)
Line __ TX6-T (Top)
J2 Green
J8C/TX-6
TX6-R (Bottom)
RX6-T (Top) Brown J8D/RX-6
RX6-R (Bottom)
Line __ TX11-T (Top)
J2 Blue
J8A/TX-11 URC,
Position 3
NOTE 2
TX11-R (Bottom)
RX11-T (Top)
Orange
J8B/RX-11
RX11-R (Bottom)
Line __ TX12-T (Top)
J2 Green
J8C/TX-12
TX12-R (Bottom)
RX12-T (Top) Brown J8D/RX-12
RX12-R (Bottom)
NOTE 1: A DATA T1/E1 line must be punched down to URC, position 1
(
TX-RX 1 to TX-RX 4). VOICE T1/E1 lines may also be punched down to URC, position 1
(TX-RX 1 to TX-RX 4) but Data and Voice are mutually exclusive.
NOTE 2: VOICE T1/E1 lines only are punched down to URC, position 2 (TX-RX 5 to TX-
RX 8) and URC, position 3 (TX-RX 9to TX-RX 12)
NOTE 3:
TX/RX signal pair punchdowns are not physically located in numerically
consecutive order on the EFIM