User's Manual
Modular Cell 4.0B and WNG24-BC cabinet handling,
placement, anchoring and grounding
2- 69
Lucent Technologies – Proprietary
See notice on first page
401-703-454
FOA Draft Issue 1
January, 2006
............................................................................................................................................................................................................................................................
.............................................................................................................................................................................................................................................................
Solar shield table
Heat exchanger and solar
shield configurations for
Modular Cell 4.0B cabinets
The following table provides the heat exchanger and solar shield
configuration for Modular Cell 4.0B primary and dual band cabinets.
The cabinet configuration depends upon the outside ambient operating
temperature range, the amplifier type, and whether the cabinet has
integrated or non-integrated power.
TABLE NOTES
NOTE 1: Heat exchangers are shipped installed, as applicable.
NOTE 2: A top solar shield (standard for all cabinets) is shipped loose with the cabinet,
to be installed in the field.
NOTE 3: The left solar shield is shipped attached to the
primary cabinet. The left solar shield is not shipped with dual band cabinets. When
installing a dual band cabinet, you would attach the left solar shield removed from the
4.0B primary cabinet.
NOTE 4: The front solar shield is shipped installed only on 40-46C non-integrated
power cabinets with 6 carriers or greater (carriers 6 through 11, as applicable)
NOTE 5: The right solar shield is shipped loose, to be installed in the field. Installation
instructions are included with the parts. The right solar shield would not be mounted
if
installing a battery cabinet or frame at the same time as the primary cabinet. When
subsequently installing a battery cabinet or frame, the right solar shield must be
removed from the primary cabinet. It will not be reused
* PCS cabinets
TEMPERATURE
RANGE
POWER TYPE HEAT EXCHANGER
TYPE REQUIRED
(NOTE 1)
SOLAR SHIELDS REQUIRED
(NOTE 2)
-40C TO +46 C INTEGRATED POWER FRONT LEFT SOLAR SHIELD (NOTE 3)
RIGHT SOLAR SHIELD (NOTE 5)
NON INTEGRATED POWER
(1 through 5 Carriers)
REAR NONE
NON INTEGRATED POWER
(6 Carriers or greater)
REAR FRONT SOLAR SHIELD (NOTE 4)
NON INTEGRATED POWER
(9 Carriers or greater) *
REAR FRONT SOLAR SHIELD (NOTE 4)
LEFT SOLAR SHIELD (NOTE 3)
-40C TO +52C INTEGRATED POWER FRONT LEFT SOLAR SHIELD (NOTE 3)
RIGHT SOLAR SHIELD (NOTE 5)
NON INTEGRATED POWER FRONT LEFT SOLAR SHIELD (NOTE 3)
RIGHT SOLAR SHIELD (NOTE 5)