Cable connections in the Modular Cell 4.0B cabinets
................................................................................................................................
............................................
8 Torque the antenna jumper cable connections at the Modular Cell 4.0B
cabinet to 221 in.-lb. (25 Nm) using the method shown in the figure
below.
Important! When connecting/disconnecting a Lucent RF
coaxial jumper cable assembly to/from any fixed panel mounted
7-16 DIN female receptacle, it is highly recommended that the
cable assembly be connected/disconnected as shown in the figure
below. Please note that the mating receptacle is not shown because
it is a fixed and secured interface. Wrenches for connecting/
disconnecting the mating RF coaxial jumper cable's 7-16 DIN
male plug, which is equipped with a rotating coupling nut, are
required.