Cable connections in the Modular Cell 4.0B cabinets
3- 13
Lucent Technologies – Proprietary
See notice on first page
401-703-454
FOA Draft Issue 1
January, 2006
............................................................................................................................................................................................................................................................
Connection of the conduit with T1/E1 lines and external user alarms
.............................................................................................................................................................................................................................................................
cables to a 4.0B primary cabinet
Important! If installing a Modular Cell 4.0B dual band cabinet
in a line up that has a 3.0, 4.0, or 4.0B primary cabinet with
integrated power, skip to How to route the T1/E1 cable(s) to a
Modular Cell 4.0B dual band cabinet in a line-up that has a Modular Cell
3.0, 4.0, or 4.0B primary cabinet with integrated power on Page 3 - 16
and continue the installation from that point.
If installing a Modular Cell 4.0B dual band cabinet in a line up
that has a 1.0, 2.0., 3.0 or 4.0 primary cabinet without integrated
power, skip to How to route the T1/E1 cable(s) to a Modular Cell 4.0B
dual band cabinet in a line-up that has a Modular Cell 1.0, 2.0, 3.0, 4.0,
or 4.0B primary cabinet without integrated power on Page 3 - 18 and
continue the installation from that point.
Connect the conduit
between the metal conduits
and the antenna cable
cover of the 4.0B primary
cabinet
Perform the following steps to connect the conduit (flexible or rigid,
depending upon local code), containing the T1/E1 and user alarm
cables, between the metal conduit and the antenna cable cover of the
4.0B primary cabinet. The metal conduit was installed as part of site
preparation.
Important! Before connecting the conduit at the 4.0B primary
cabinet, the T1/E1 and external user alarm cables most be pulled
through the unconnected conduit and into the antenna cable cover
................................................................................................................................
............................................
1 Locate the metal conduit for the T1/E1 and user alarm cables, and, if
installed, remove the end cap from the metal conduit.
................................................................................................................................
............................................
2 Remove the end panel from the antenna cable cover, and then remove
the 2-inch hole cover from the left panel on the rear of the cover.
................................................................................................................................
............................................
3 Pull the T1/E1 and user alarm cables out of the metal conduit.