User's Manual

Cable connections in the Modular Cell 4.0B cabinets
3- 27
Lucent Technologies – Proprietary
See notice on first page
401-703-454
FOA Draft Issue 1
January, 2006
............................................................................................................................................................................................................................................................
Routing of T1/E1 and user alarm cables into a Modular Cell 4.0B
.............................................................................................................................................................................................................................................................
cabinet
Overview
This procedure module provides instructions for the routing of the T1/
E1 and user alarm cables into the Modular Cell 4.0B primary or 4.0B
dual band cabinet.
T1/E1 installation will vary depending upon the Universal Radio
Controller (URC or URCII) in use in the cabinet being installed. A
URC accepts a maximum of twelve TI/E1 lines, and requires one T1/
E1 cable. A URCII accepts a maximum of twenty
TI/E1 lines, and will
require two T1/E1 cables if the additional eight T1/E1 lines are utilized.
Step-by-step instructions are provided for the following tasks.
Install the EMI / RFI cord grip seals with T1/E1 and user alarm
cables
3 - 29
Prepare the T1/E1 and user alarm cables for punchdown and
ground connection at the facilities interface module
3 - 33