User's Manual
3-28
Lucent Technologies – Proprietary
See notice on first page
401-703-454
FOA Draft Issue 1
January, 2006
...........................................................................................................................................................................................................................................................
Cable connections in the Modular Cell 4.0B cabinets
Description of T1/E1 and
user alarm cables
The Modular Cell 4.0B cabinets require one T1/E1 cable if equipped
with the "URC" Universal Radio Controller (1 - 12 T1/E1 lines). The
Modular Cell 4.0B cabinet requires two T1/E1 cables if equipped with
"URCIIs", and the additional eight T1/E1 lines (13 - 20) are utilized.
The recommended cable is specified in Flexent
Modular Cell 4.0/4.0B
Site Preparation Guidelines, 401-703-413.
Important! Installation procedures contained in this document
are based on the recommended 24-pair cable. Refer to the table
below. If a different cable is used, the wire colors may vary.
Important! The outside diameter of the twisted-pair cable must
be within the range of 6 mm (0.24 inches) to 12 mm (0.47 inches),
in order to fit through the cord grip seal supplied on the Modular
Cell 4.0B cabinet, and also be firmly held in place with proper
grounding.
Color Code specified cable
Pair No. Colors
1 White-Blue Blue-White
2 White-Orange Orange-White
3 White-Green Green-White
4 White-Brown Brown-White
5 White-Slate Slate-White
6 Red-Blue Blue-Red
7 Red-Orange Orange-Red
8 Red-Green Green-Red
9 Red-Brown Brown-Red
10 Red-Slate Slate-Red
11 Black-Blue Blue-Black
12 Black-Orange Orange-Black
13 Black-Green Green-Black
14 Black-Brown Brown-Black
15 Black-Slate Slate-Black
16 Yellow-Blue Blue-Yellow
17 Yellow-Orange Orange-Yellow
18 Yellow-Green Green-Yellow
19 Yellow-Brown Brown-Yellow
20 Yellow-Slate Slate-Yellow
21 Violet-Blue Blue-Violet
22 Violet-Orange Orange-Violet
23 Violet-Green Green-Violet
24 Violet-Brown Brown-Violet