User's Manual

RF cable connections between existing Modular Cell
cabinets and a 4.0B dual band cabinet
6- 13
Lucent Technologies – Proprietary
See notice on first page
401-703-454
FOA Draft Issue 1
January, 2006
............................................................................................................................................................................................................................................................
15 MHZ INTER-FRAME CABLES: LINE-UP 2
LINE-UP PRIMARY CABINET CONNECTION PROCEED TO:
The existing cable connections from the
G-1 cabinet in the 4.0 primary cabinet
remain the same as they were. A kit is
s
upplied to install two 15MHz splitters in
the
G-1
cabinet. Installation instructions
are supplied with the kit. 15MHz
connections from all three cabinets are
made to these splitters as shown in the
illustration below.
"Route and connect
the GPS cable",
Line-up 2
4.0B Dual Band with
4.0 G-1 and 4.0 Primary
G-2
G-1
PRI
OUT 2
OMU-XX
OUT 1
OMU-XX
4.0B DUAL BAND
G-2 CABINET
4.0 PRIMARY CABINET
4.0 G-1 CABINET