User's Manual

Finishing the installation
7- 7
Lucent Technologies – Proprietary
See notice on first page
401-703-454
FOA Draft Issue 1
January, 2006
............................................................................................................................................................................................................................................................
Digital meter - no symbol or positive symbol = correct
connection.
Digital meter - negative symbol = incorrect connection.
Analog meter - positive deflection = correct connection.
Analog meter - negative deflection = incorrect connection.
All of the above assume correct meter lead connection.
................................................................................................................................
............................................
3 Repeat the test in the previous step, for the battery connector to be
plugged into the one already tested.
................................................................................................................................
............................................
4 Rewire any incorrectly wired battery cables. Use the procedure Install
batteries in a Modular Cell 4.0B cabinet, in Chapter 5, Page 5 - 5.
Important! Before performing the next step, be sure that AC
power is connected to the Modular Cell 4.0B or 4.0B dual band
cabinet, all AC circuit breakers are ON, and AC power is turned
on at the main panel.
................................................................................................................................
............................................
5 Connect the battery connectors together.
+
_
+
_
26.25
+
_
NEGA-
TIVE
POSITIVE
DEFLECTION
NEGATIVE
DEFLECTION
ANALOG
DIGITAL
BATTERY
CONNECTOR
*
EXAMPLE VOLTAGE
ONLY