Finishing the installation
Connect the unterminated
end of the RF antenna
jumper cables to the
Modular Cell 4.0B primary
or 4.0B dual band cabinet
Important! If both ends of the antenna jumper cables are
terminated, skip to Connect a terminated end of the outdoor RF
antenna jumper cables to the Modular Cell 4.0B primary or 4.0B dual
band cabinet on Page 7 - 12 to continue the installation.
The Modular Cell 4.0B primary or 4.0B dual band cabinet requires six
RF antenna jumper cables. The jumper cables may be unterminated on
one end. This end will be terminated and attached to the RF connectors
on the applicable Modular Cell cabinet, which is reached through the
entry openings on the antenna cable cover of the cabinet. The jumper
cables are terminated on the other end with a 7/16-inch straight male
DIN connector. This end will connect directly to the surge suppressors
on each RF antenna at the outdoor cable rack support. Refer to the
figure on Page 7-15
Use the following procedure to connect the RF antenna jumper cables
to the Modular Cell 4.0B primary or 4.0B dual band cabinet.
................................................................................................................................
............................................
1 Cut the unterminated end of the cable to the correct length. Allow
adequate slack for a drip loop and cut the cable to the correct length.
Refer to the figure on Page 7-15.
................................................................................................................................
............................................
2 Label both ends of each RF antenna jumper cable: S1D0, S1D1, S2D0,
S2D1, S3D0, S3D1.
Important! When performing the next step, do not prepare the
unterminated end of the cable for the subsequent attachment of the
connector. The sharp edges that would result will damage the
rubber boot when it is slid onto the cable. Refer to the figure on
Page 7-9.