Modular Cell 4.0B and WNG24-BC cabinet handling,
placement, anchoring and grounding
................................................................................................................................
............................................
3 Start threading the anchoring bolts, but leave them loose (they will be
tightened later).
Important! If not installing the first battery cabinet mounting
base at this time, tighten all four anchor bolts to 18 ft-lb (24 Nm)
and then skip to Cabinet handling on Page 2 - 21 to continue the
installation.
................................................................................................................................
............................................
4 Repeat Steps 1 through 4 for the first battery cabinet mounting base and
then attach it to the Modular Cell 4.0B mounting base using the four
bolts, flat washers and lock washers supplied. Refer to the figure on
Page 2-12.
Important! If not installing the second battery cabinet
mounting base at this time, tighten all eight anchor bolts to 18 ft-lb
(24 Nm) and then skip to Cabinet handling on Page 2 - 21 to
continue the installation.
................................................................................................................................
............................................
5 Repeat Steps 1 through 4 for the second battery cabinet mounting base
and then attach it to the first battery cabinet mounting base (as shown
below) using the four bolts, flat washers and lock washers supplied.
................................................................................................................................
............................................
6 Tighten all twelve anchor bolts to 18 ft-lb (24 Nm), and then skip to
Cabinet handling on Page 2 - 21 to continue the installation.
FIRST WNG BATTERY CABINET MOUNTING BASE
OR
SECOND WNG BATTERY CABINET MOUNTING
BASE
FLAT
WA SH E R
LOCK
WASHE R
FLAT
WA SH E R
FLAT
WA SH E R
BOLT
BOLT
MOUNTING
BASE
SHIM
(EXAMPLE)
PRIMARY CABINET MOUNTING BASE
OR
FIRST WNG BATTERY CABINET MOUNTING BASE