Modular Cell 4.0B and WNG24-BC cabinet handling,
placement, anchoring and grounding
................................................................................................................................
............................................
5 Attach the dual band mounting base to the previous Modular Cell
mounting base using the four bolts, flat washers and lock washers
supplied. Refer to the figure below.
................................................................................................................................
............................................
6 Tighten each of the eight zone 3 and 4 nuts to 58 ft.-lb (79 Nm), as
shown below.
BOLT
FLAT
WA SH ER
LOCK
WA SH ER
DUAL BAND
CABINET
MOUNTING
BASE
PREVIOUS MODULAR CELL
CABINET MOUNTING BASE
FLAT
WASHER
PLATE
WA SH ER
THREADED
ROD
NUT