User's Manual

A- 9
Lucent Technologies – Proprietary
See notice on first page
401-703-454
FOA Draft Issue 1
January, 2006
............................................................................................................................................................................................................................................................
How to place and attach the EZBFo battery base module outer frame
.............................................................................................................................................................................................................................................................
and mark, drill, and set anchors
Overview
In this module the installer will perform the following procedures:
Unstrap the front panel and place it on the top panel of the outer
frame, not detaching the lanyard cable
Attach the conduit to the battery base module outer frame
Place the battery base module outer frame into position with the
conduit into the Modular Cell cabinet and attach conduit
Remove the top and filter panels, not detaching the lanyard cable
If anchor holes have not been drilled:
Mark the anchor holes
Detach conduit at Modular Cell cabinet, move the battery
base module outer frame aside, and drill the anchor holes
Reposition the battery base module outer frame with the
conduit into the Modular Cell cabinet and attach the conduit
to Modular Cell cabinet
Set the 1/2 inch drop in anchors
This module contains the following procedures:
Before you begin
If installing a EZBFo battery add-on module only, proceed to How to
install an EZBFo battery add-on module on an existing EZBFo battery module
on Page A - 76 to continue the installation. If installing an EZBFo
battery base module, continue as instructed.
Important! If the Modular Cell cabinet is equipped with
internal batteries, disconnect the battery connector or connectors
inside of the cabinet before proceeding.
Place and attach a battery base module to the Modular Cell cabinet
or the first battery base module using the applicable conduit
A - 10
Remove the top and filter panels from the battery base module A - 14
Mark and drill the anchor holes A - 16
Set the 1/2-inch diameter drop-in anchor A - 18