Route and attach the fuse
alarm cable to the fuse
alarm switch in the battery
base module
Refer to the figure below, and perform the following steps to route and
attach the fuse alarm cable to the fuse alarm switch in the battery base
module.
................................................................................................................................
............................................
1 Refer to the figure below for an illustration of the connectors to be
attached.
................................................................................................................................
............................................
2 Connect the cable spade lugs to the fuse alarm switch as shown in the
figure below: SW2-1 to lug 1 (COMMON) and SW2-4 to lug 4. (NO).
................................................................................................................................
............................................
3 Route and dress the cable using the cable ties and self-stick anchors
provided.
FUSE ALARM
ACTUATOR AND
SWITCH
INSIDE LEFT
VIEW
F
USE ALARM
C
ABLE FROM
T
HE MODULAR
C
ELL CABINET
FUSE ALARM
ACTUATOR
1
2
(NOT
USED)
4
SW2-4
SW2-1
RTN-1
RTN-2
1
4
2
FUSE ALARM
SWITCH
FRONT VIEW