User's Manual

A- 54
Lucent Technologies – Proprietary
See notice on first page
401-703-454
FOA Draft Issue 1
January, 2006
...........................................................................................................................................................................................................................................................
Route and attach the fan
power and alarm cable in
the battery base module
Important! The fan, temperature sensor, and cable are located
on the front panel of the battery module. Therefore the front panel
must be connected to the outer frame via the lanyard cable when
connecting the fan power and alarm cable.
Refer to the figure below, and perform the following steps to route and
attach the fan power and alarm cable in the battery base module.
................................................................................................................................
............................................
1 Locate the fan power and alarm cable harness from the Modular Cell
cabinet. Refer to the figure below
................................................................................................................................
............................................
2 Connect J9 on the fan power and alarm cable harness to connector P9 at
the fan unit on the front panel of the battery base module. Refer to the
figure below.
................................................................................................................................
............................................
3 Route and dress the cable using the cable ties and self-stick anchors
provided. The slack allowed in the cable must be at least as long as the
lanyard cable.
A
TTACH FAN
C
ABLE J9 TO P9
H
ERE
T
he parts illustrat
ed
are mounted on th
e
inside of the front
panel