User's Manual

A- 55
Lucent Technologies – Proprietary
See notice on first page
401-703-454
FOA Draft Issue 1
January, 2006
............................................................................................................................................................................................................................................................
Route and attach the
intrusion alarm cable in the
battery base module
Refer to the figure below, and perform the following steps to route and
attach the intrusion alarm cable in the battery base module.
Important! On battery modules that have a front door instead of
a panel, the intrusion alarm switch is located at the bottom front,
on the opposite side from the door hinge, either the left or right
side, as applicable. Refer to the Step 3 figure on page A - 10
................................................................................................................................
............................................
1 Locate the alarm cable harness from the Modular Cell cabinet and the
double spade lugs marked SW1- NC and SW1-Com. Connect the SW1-
COM spade lug to the COMMON connector on the intrusion alarm
switch as shown in the figure below, item 1.
................................................................................................................................
............................................
2 Connect the SW1- NC spade lug to the CLOSED connector on the
intrusion alarm switch as shown in the figure below, item 2.
................................................................................................................................
............................................
3 Route and dress the cable using the cable ties and self-stick anchors
provided.
SW1-COM
SW1-NC
OPEN
(NOT USED)
CLOSED
INTRUSION ALARM CABLE
FROM THE
MODULAR CELL
CABINET
INTRUSION
ALARM SWITCH
IN THE BATTERY
MODULE
SPADE LUG (1 of 2)
1
2
COMMON
OPEN
CLOSED
COMMON