User's Manual

RRH clearances
Minimum clearances table
The following table provides the minimum wall mount clearances recommended around
the RRH.
RRH Clearances mm (inches) Comments
Front 1000 (39.37) Installation access
Rear 70 (2.76) Zero rear clearance is allowed using
supplied mounting brackets.
Side clearance 300 (11.81) Air flow
To secure RRH body on the mounting kit
To change the shield cover.
Top 300 (11.81) Air flow
Bottom 500 (19.67) Conduit routing
Minimum clearances graphics for RRH
The following graphic is an example of minimum clearances between RRHs.
TX/RX 0
RX 1
RRH
TX/RX 0
RX 1
TX/RX 0
RX 1
RRH
RRH
To wall
or
obstruction
300 mm
(11.81 in.)
300 mm
(11.81 in.)
300 mm
(11.81 in.)
Site requirements RRH clearances
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
5-4
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W
NN-20500-305 UA08.1
Issue 0.7 November 2011