User's Manual

Site requirements for floor stand installations
Overview
This topic describes site requirements for RRH installation on a floor, such as the location
and drilling of anchor holes for the floor stand.
Anchor hole specifications
The following table provides anchoring specifications for seismic zones 0 through 4.
Equipment Seismic
zone(s)
Anchor type Number of
holes
Hole size
mm
(inches)
Hole depth
mm (inches)
Torque Nm
(lbf in)
Floorstand 0, 1, 2 1/2" Dia
drop-in
416mm
(5/8 in.)
50 mm
(2 in.)
24 (212)
3, 4 M12 x 125
mm
418mm
(11/16 in.)
100 mm
(4 in.)
79 (700)
Floor stand
The floor stand shown below is required to install the RRH to the floor.
Site requirements Site requirements for floor stand installations
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W
NN-20500-305 UA08.1
Issue 0.7 November 2011
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
5-13
P
RELIMINARY
P
RELIMINARY