Transport Service Switch Specifications
Alcatel-Lucent 1850 TSS-160 | Release 3 | Data Sheet 3
Ethernet forwarding criteria
• Port
• PortplusMAC
• PortplusVLAN
• PortplusMACplusVLAN
• PortplusMACplusVLANplus
Prio bits
• Unicasttraffic
• Multicasttraffic
• Broadcasttraffic
IGMP functionality
• InternetGroupManagement
Protocol(IGMP)snooping
• IGMPproxy
• IGMPfastleave
ATM functionality
• Pseudo-wireemulationedgeto
edge(PWE3):ATM-PWE3gateway
• OC-3/STM-1ATMunchannalized
• ATMvirtualpathidentifier/virtual
channelidentifier(VPI/VCI)
N:1mappingwithPWE3static
configuration
• ATMQoS,OAMF4,F5:PWEOAM
T-MPLS functionality
• Dataplane:T-MPLS,MPLS
• T-MPLSOAM:CV,automaticpro-
tection switching (APS), forward
defect indication (FDI)
• TunnelLinProtection1:1
• Ethernetline(E-line),E-LAN
and E-Tree
SONET/SDH functionality
• Cross-connection
• Termination
• EthernetmappingoverSONET/SDH
¬Genericframingprocedure:
GFP,G.7041
• Virtualconcatenation(VCAT)
• Linkcapacityadjustmentscheme
(LCAS)
•Performancemonitoring
• HOandLOcapabilities
DWDM functionality
• Nodeconfigurations
¬ Terminal
¬ In-line amplifier (ILA)
•Networkconfigurations
¬ Point-to-point
¬ Linear
¬ Ring
¬ Mesh
Protection
• Ethernetnetworkprotection
¬RSTP:802.1w
¬MSTP:802.1s
¬ Link aggregation
• T-MPLSnetworkprotection
¬TunnelLinProtection1:1
•SONET/SDHnetworkprotection
¬Single-anddual-endedAPS1+1
¬ Subnetwork Connection
Protocol (SNCP), unidirectional
path-switchedring(UPSR)
¬ Multiplex Section-Protection
Ring(MSPRING)2Fbidirectional
lineswitchingring(BLSR)
•Equipmentprotection
¬ Power protection
¬ Controller protection
¬Universalswitchprotection
G-MPLS control plane
• T-MPLStunnelsetup
• TDMHOpathsetup
Management
• Alcatel-Lucent1350Optical
Management System (OMS)
• TL1
• Zero-installationcraft(ZIC)terminal
• Commandlineinterface(CLI)
• SimpleNetworkManagement
Protocol (SNMP)
• SecureShell(SSH)v2/Secure
Sockets Layer (SSL) for secure
connection
Physical specifications
ANSI
Dimensions: Alcatel-Lucent 1850
TSS-160 subrack
• Subrackdimensions
¬Height:304mm(12.0in.)
¬Width:498mm(19.6in.)
¬Depth:305mm(12.0in.)
or 356 mm (14.0 in.)
• Designedtobeinstalledina
standard ANSI rack
¬Height:2.13m(7.0ft.)
¬Width:660mm(26.0in.)
¬Depth:305mm(12.0in.)
or 356 mm (14.0 in.)
Power and cooling
• Powersupply:DCfeed(-48-VDC
nominal)
• Powersupply:-58-V
• Powerconsumption:upto2000W
• Cooling:forcedair
Environment
• Operatingtemperature:
-5°Cto+45°C(23°Fto113°F)
• Relativehumidity:0%to90%,
non-condensed
Regulatory compliance
• CEandULcertification
• NEBSlevel3
• FCCpart15classA
ETSI
Dimensions: Alcatel-Lucent 1850
TSS-160 subrack
• Subrackdimensions
¬Height:304mm(12.0in.)
¬Width:498mm(19.6in.)
¬Depth:290mm(11.4in.)
• Designedtobeinstalledina
standard ETSI rack
¬Height:2.20m(7.2ft.)
¬Width:600mm(23.6in.)
¬Depth:300mm(11.8in.)
Power and cooling
• Powersupply:DCfeed(-48-VDC
nominal)
• Powersupply:-65-V
• Powerconsumption:upto2000W
• Cooling:forcedair
Environment
• Operatingtemperature:
-5°Cto+45°C(23°Fto113°F)
• Relativehumidity:0%to90%,
non-condensed
Regulatory compliance
•CEcertification
• Operatingconditions:
ETS 300 019, Class 3.2
•Storageconditions:
ETS 300 019, Class 1.2
•Transportationconditions:
ETS 300 019, Class 2.2
• Electrostaticdischarge(ESD)/elec-
tromagneticcompatibility(EMC):
ETS 300 386 “Telecommunications
Center”