10. Internal tracking ID: 805
Problem Description: Users within a user group cannot be modified.
Impact: Accountability issues. Convoluted method for modifying individual user
configurations within a user group.
Workaround/s: Instead of editing the user group, change the user group for the
desired users.
11. Internal tracking ID: 1127
Problem Description: If the user's "full name" is missing and you ask for the user
status then the operation fails.
Impact: Accountability issues. Not able to see the user status for such users.
Workaround/s: Never leave the full name of the user blank.
A
UTO
VPN
12. Internal tracking ID:
Problem Description: AES is not supported by the encryption acceleration
hardware in the card. However the AES algorithm will automatically work using
the software based encryption. The encryption acceleration hardware in the
gateway supports AES.
Impact: Reduced throughput for the clients making use of AES.
Workaround/s: Avoid using AES if not required.
A
CTIVE
D
IRECTORY
I
MPORT
13. Internal tracking ID: 1277
Problem Description: While importing a user who is already present in the
management system database, a message saying “base key foreign key integrity
constraint” is displayed.
Impact: Confusion to the administrator.
Workaround/s: Ignore the message, the operation is successful.
14. Internal tracking ID: 1305
Problem Description: Display name of the user not imported.
Impact: Difficult to identify the imported users.
Workaround/s: Enter the display name manually for the imported users.
P
ERSONAL
F
IREWALL
15. Internal tracking ID: 1001
Problem Description: If a change is made to a host or service group that is already
used in a personal firewall policy then the changes are not reflected in the policy.
Impact: Desired changes are not reflected in the personal firewall policy.