User guide

DC Power Supply Considerations
DC power supplies have the following additional considerations:
Connect to a -48V or -60V reliably grounded DC SELV source.
Use common DC return connections for the DC power supplies. The DC return terminal conductor
should be connected to the equipment frame.
The Branch Circuit Overcurrent Protection must be rated a Maximum of 15A.
Use 12AWG solid conductors only.
A readily accessible disconnect device that is suitably approved and rated shall be incorporated in the
field wiring.
Twisted pair wire (red and black) for a DC power supply
Connecting Chassis to Power Source
AC Power Supply Connections
Since the power cord is the switch’s only disconnect device, it should be plugged into an easily accessible
outlet. In the event that your power cord is lost or damaged, refer to the specifications below.
Powering On a Chassis
Follow the steps below to power on the chassis using and AC power source:
1 Connect the IEC-60320-C15 end of the supplied power cord to the chassis.
2 Connect power supply to AC power source.
3 Monitor the chassis as it boots.