User Manual

4
AlcAtel-lucent OmniSwitch 6855
ALCATELLUCENT ENTERPRISE DATA SHEET
COMPLIANCE AND
CERTFICATIONS
Commercial
EMI/EMC
• FCC CRF Title 47 Subpart B (Class A)
• VCCI (Class A)
• AS/NZS 3548 (Class A)
• CE marking for European countries (Class A)
• EN 5502:2006 (Emission Standard)
• EN 61000-3-3:1995 +A2:2005
• EN 61000-3-2:2006
• EN 55024:1998 +A1:2001 +A2:2003
(Immunity Standards)
¬ EN 61000-4-2: 1995+ A1:1998
+A2:2001
¬ EN 61000-4-3:2006
¬ EN 61000-4-4:2004
¬ EN 61000-4-5:2006
¬ EN 61000-4-6:2007
¬ EN 61000-4-8:1993 +A1:2001
¬ EN 61000-4-11:2004
• IEEE802.3: Hi-pot Test (2250 V DC on all
Ethernet ports)
• EN 50121-4
neBS**
• GR-63-CORE (temperature, humidity,
altitude, contamination)
• GR-1089-CORE Issue 4 (section 2-3)
• GR-1089-CORE Issue 4 (section 3.2, 4-10)
Industrial
• IEC 60870-2-2 (operational temperature)
• IEC 60068-2-1 (temperature type test cold)
• IEC 60068-2-2 (temperature type test – hot)
• IEC 60721-3-1: Class 1K5 (storage
temperature)
• IEC 68-2-30: 5% to 95% non-condensing
humidity
• IEC 60255-21-2 (mechanical chock)
• IEC 60255-21-1 (vibration)
EMI/EMC
• EN 61131-2
• EN 61000-6-4: 2007 (emission)
• EN 61000-6-2: 2005 (immunity)
• EN 55024: 1998 (immunity)
¬ IEC 61000-4-3
¬ IEC 61000-4-12
¬ IEC 61000-4-16
¬ IEC 61000-4-17
¬ IEC 61000-4-29
• IEC 60255-5
• IEC 61850-3 (Electric Power Substations)
• IEC 62236-4:2008 – Railway applications;
Electromagnetic compatibility – Part 4
• EN 50121-4: 2006 for Class A device
• IEEE 1613 (C37.90.x)
• C37.90.3 (ESD)
• C37.90.2 (Radiated RFI)
• IEEE 1613 C37.90.1 (Fast Transient)
• IEEE 1613 C37.90.1 (Oscillatory)
• IEEE 1613 C37.90 (H.V. Impulse)
• IEEE 1613 C37.90 (Dielectric Strength)
Military
• MIL-STD-810F (shock and vibration)***
• MIL-STD-901D (shock)**
• MIL-STD-167-1 (vibration)**
• MIL-STD-810F**: Methods 500, 501, 502,
503, 504, 505, 506, 507, 508, 509, 510,
512, 514, 515, 516, 520, 521
• MIL-STD-461E**: CE101, CE102, CS101,
CS114, CS115, CS116, RE101, RE 102,
RS101, RS103
Safety agency certifications
• US UL 60950
• IEC 60950-1:2001; all national deviations
• EN 60950-1: 2001; all deviations
• CAN/CSA-C22.2 No. 60950-1-03
• NOM-019 SCFI, Mexico
• AS/NZ TS-001 and 60950:2000, Australia
• UL-AR, Argentina
• UL-GS Mark, Germany
• EN 60825-1 Laser
• EN 60825-2 Laser
• CDRH Laser
* Note: Class A with UTP cables.
** Contact for availability
*** All models except OS6855-P14 are MIL-810F
compliant
DETAILED PRODUCT FEATURES
Interface and speeds
Switching capacity
• OS6855-U10/-U10D: 10 Gbps Full Duplex
or 20 Gbps aggregate
• OS6855-14/-14D/ -P14: 14 Gbps Full
Duplex or 28 Gbps aggregate
• OS6855-24/-24D/-24DL: 24Gbps Full
Duplex or 48Gbps aggregate
• OS6855-U24X/-U24XD/-U24XDL: 48Gbps
Full Duplex or 96Gbps aggregate
Layer 2 throughput ( Mp/s)
• OS6855-U10/-U10D: 14.9 Mp/s
• OS6855-14/-14D/-P14: 20.8 Mp/s
• OS6855-24/-24D/-24DL: 35.7 Mp/s
• OS6855-U24X/-U24XD/-U24XDL:
65.5 Mp/s
Stacking capacity for OS6855-U24X
• Full duplex/aggregated: 20/40 Gbps
Layer 2 switching
• Maximum number of configured VLANs:
4K
• Maximum MAC addresses per system: 16K
• Jumbo frame support: 9216 bytes
Simplified manageability
Management interfaces
• Intuitive, familiar Alcatel-Lucent CLI
reduces training costs
• Easy to use, point-and-click, web-based
element manager (WebView) with built-in
help for easy configuration
• Integrated with Alcatel-Lucent OmniVista™
products for network management
• Full configuration and reporting using
SNMPv1/2/3 across all OmniSwitch
families to facilitate third-party network
management system integration
• Remote switch access using Telnet or
Secure Shell (SSH)
• File upload using USB, TFTP, FTP, SFTP, or
SCP for faster configuration
• Human-readable ASCII-based configuration
files for off-line editing, bulk configuration
and out-of-the-box auto-provisioning
Monitoring and troubleshooting
• Local (on the flash) and remote server
logging: Syslog and command log
• Port-based mirroring for trouble- shooting
and lawful interception; supports four
sessions with multiple sources-to-one
destination
• Policy-based mirroring allows selection of
the type of traffic to mirror by using QoS
policies
• Remote port mirroring facilitates passing
mirrored traffic through the network to a
remotely connected device
• Port monitoring feature allows capture
of Ethernet packets to a file to assist in
troubleshooting
• sFlow v5 and RMON for advanced
monitoring and reporting capabilities for
statistics, history, alarms and events
• IP tools: ping and trace route
• Y.1731 and IEEE 802.1ag Ethernet
operations, administration and
maintenance (OA&M): Connectivity
Fault Management and performance
measurements (layer-2 ping and link trace)
• IEEE 802.3ah Ethernet in the First Mile
(EFM) for link monitoring, remote fault
detection, and loop- back control (layer-1
ping)