User guide

OmniSwitch 6900 Chassis Chassis and Power Supplies
page 2-4 OmniSwitch 6900 Hardware Users Guide December 2013
OS6900-X20 and OS6900-X40 Chassis Specifications
Note. For OS6900-T20 and OS6900-T40 chassis specifications, please refer to page page 2-8.
1
Fully populated weights include fan tray, all installable power supplies and expansion modules. These
figures do not include transceivers.
2
Fully populated front panel (no expansion modules). See individual expansion modules for power
consumption information.
Chassis Width (with brackets)
Chassis Width (without brackets)
48.2 cm (19 inches)
43.3 cm (17.05 inches)
Chassis Height 4.4 cm (1.73 inches or 1RU)
Overall Chassis Depth 55.9 cm (22 inches)
OS6900-X20 Chassis Weight (w/factory-installed fan tray only) 7.61 kg (16.8 lbs)
OS6900-X20 Chassis Weight (fully populated)
1
10.21 kg (22.5 lbs)
OS6900-X40 Chassis Weight (w/factory-installed fan tray only) 7.78 kg (17.15 lbs)
OS6900-X40 Chassis Weight (fully populated)
1
10.86 kg (23.95 lbs)
Power Supply Bays 2
OS6900-X20 Power Consumption (SFP+ transceivers)
2
181W**
OS6900-X40 Power Consumption (SFP+ transceivers)
2
242W**
Operating Temperature (Tmra):
Front-to-rear airflow (all models)
Rear-to-front airflow (all models)
0°C to 40°C (32°F to 104°F)
0°C to 40°C (32°F to 104°F)
Storage Temperature -10°C to +70°C (14°F to 158°F)
OS6900-X20 Temp Warning Threshold (front-to-rear airflow) 64°C (147°F)
OS6900-X20 Temp Warning Threshold (rear-to-front airflow) 58°C (136°F)
OS6900-X40 Temp Warning Threshold (front-to-rear airflow) 68°C (154°F)
OS6900-X40 Temp Warning Threshold (rear-to-front airflow) 60°C (140°F)
OS6900-X20 Temp Danger Threshold (front-to-rear airflow) 72°C (161°F)
OS6900-X20 Temp Danger Threshold (rear-to-front airflow) 70°C (158°F)
OS6900-X40 Temp Danger Threshold (front-to-rear airflow) 82°C (179°F)
OS6900-X40 Temp Danger Threshold (rear-to-front airflow) 70°C (158°F)
Operating Humidity 5% to 95% non-condensing
Storage Humidity 5% to 95% non-condensing