User's Manual

3-28
3.15.5
MCS-11 Connections
When MCS is selected to be placed on one of the three service channels and then RSS is
enabled and properly addressed, applicable ports on the controller module are enabled.
This allows the user to interface external MCS-11 Monitor and Control System equipment
at any or all four connectors on the backplane (J307, J308, J309, and J310). Two connec-
tors (J308 and J309) are synchronous, parallel, data ports and provide CLK outputs. Con-
nectors J307 and J310 are asynchronous ports.
For proper operation, MCS-11 must be provisioned using the following guidelines:
a.
MCS-11
must be selected as one of the service channels.
b. MCS must be assigned a valid address
c. The
MCS RSS
must be set to
ON
for each radio with a unique RSS address. Refer to
Appendix B on the attached CD for address details. At a site, typically only one RSS is
turned on. Station scanners at all other radios at that site are normally jumpered to the
RSS enabled radio to allow access to their detail scanners. If station scanners are prop-
erly wired, detail scanners always respond, regardless of whether RSS is provisioned
ON
or
OFF
.
Table 3-7 RS-232 Mating Cable Wiring and Color Codes
J312/J313 MDR-8000 J312/J313 J312/J313 MDR-8000
FUNCTION END 1 WIRE COLOR PAIR WIRE COLOR END 2 FUNCTION
NOT USED 01 BLACK 1 BLACK 01 NOT USED
NOT USED 06 RED 1 RED 06 NOT USED
RS-232 OUT/
RS-232-1 OUT*
02 BLACK 2 BLACK 03 RS-232 IN/
RS-232-1 IN*
NOT USED 07 WHITE 2 WHITE 08 NOT USED
RS-232 IN/
RS-232-1 IN*
03 BLACK 3 BLACK 02 RS-232 OUT/
RS-232-1 OUT*
NOT USED 08 GREEN 3 GREEN 07 NOT USED
NOT USED/
RS-232-2 OUT*
04 BLACK 4 BLACK 04 NOT USED
/
RS-232-2 OUT*
NOT USED/
RS-232-2 IN*
09 BLUE 4 BLUE 09 NOT USED/
RS-232-2 IN*
GND 05 BLACK 5 BLACK 05 GND
NOT USED 10 YELLOW 5 YELLOW 10 NOT USED
*J312 on CommPak Radio