User's Manual

2-6
Figure 2-3 XMTR Manual Switch Using USI Control Screen
Controller Switch
Perform I/O manual switch (Figure 2-1) using controls on front panel of controller module.
USI Switch
Perform I/O manual switch (Figure 2-4) using the USI control screen.
File
Controls -- MDR-8000 DS3
View Setup Options
Alarm Status Performance Station Alarm User Control ProvisioningAnalog Monitor
F4 F5 F6 F7 F8 F9
LOCAL CONTROLS
Communicating*
ELMC Address:
Description:
SILVERTON
A Transmitter On Line
B Transmitter On Line
A Receiver On Line
B Receiver On Line
A I/O On Line
B I/O On Line
A ATPC HIGH Power Lock
B ATPC HIGH Power Lock
A ATPC LOW Power Lock
B ATPC LOW Power Lock
J7915
IN-SERVICE
A I/O LOOPBACK
Line 1 loopback
Line 2 loopback
Line 3 loopback
B I/O LOOPBACK
Control #1
Control #2
Control #3
Control #4
Control #5
Control #6
SYSTEM LOOP-BACK
DS1 LINE LOOP-BACK RCV to XMT
USER CONTROLS
Thursday, November 30, 2000 1:44:19 PM USI Version R1.02 Controller Version R1.02
LMW-5076-SM
06/12/04
1. SELECT XMTR TO PUT IN-SERVICE.
2. SELECT YES ON CONFIRMATION MESSAGE
TO ENABLE FUNCTION.
3. VERIFY GREEN IN-SERVICE STATUS CIRCLE DISPLAYS.
Switching the radio transmitter may momentarily interrupt
traffic. Switching I/Os will momentarily interrupt traffic and
auxiliary channel service. Before switching, obtain permission
from the proper authority.
CAUTION
Possibility of
Service