User's Manual

3-47
3.17.4 Station Alarm Wiring
See Figure 3-28. Use wire wrap adapter PN 695-4171-002 to connect station alarm inputs
to the AE-27A Relay Interface module, via connector J305, in each rack. A typical connec-
tion scenario is shown. The station/shelf alarm for MCS-11 address A1A (MCS-11 alarm
point 1) is connected by software. The station alarms for MCS-11 address A1B and A1C are
assigned to MCS-11 Alarm points 2 and 3, respectively.
Figure 3-28 Alarm and Status Relays/TBOS Interconnect