Product Info

Table Of Contents
MDR-8000 Series Radios 3DH03220
General Issue 6, July 2002
1-34
CONTROL INPUTS
Number of Inputs 9
Input Voltage 0 to 5 V dc, diode protected
Current Limiting Resistor 10 kohm
Pull-Up Resistor 100 kohm
ALARM/STATUS INPUTS
Number of Inputs 16 (13 through 16 are not available if TBOS is used)
Input Voltage 0 to 5 V dc, diode protected
Current Limiting Resistor 10 kohm
Pull-Up Resistor 100 kohm
Alarm State Logic 0
Non-Alarm State Logic 1
RELAY ALARM/STATUS OUTPUTS ALL RELAYS DEFAULT TO OPEN IF CARD POWER IS LOST,
EXCEPT POWER SUPPLY ALARMS, WHICH DEFAULT TO
GROUND.
Number of Alarm Outputs 8
Number of Status Outputs 7
Activated State Closure to ground
Maximum Contact Rating 0.5 A, 100 V
Relay Control Outputs All relays default to open if card power is lost.
Number of Outputs 6
Activated State Closure to ground
Maximum Contact Rating 0.5 A, 100 V
CONTROL STATUS INPUTS
Number of Inputs 6
Input Voltage 0 to 5 V dc, diode protected
Current Limiting Resistor 10 kohm
Pull-Up Resistor 100 kohm
Table 1-5 (Cont.) OSS External Interface Requirements
ITEM CHARACTERISTICS