- 1 General
- 1.1 INTRODUCTION
- 1.2 STANDARD FEATURES
- 1.3 NAMING CONVENTION
- 1.4 ORDERING INFORMATION
- 1.5 SYSTEM CONFIGURATIONS
- 1.6 RADIO CONFIGURATIONS
- 1.7 FEATURES AND OPTIONS
- 1.7.1 Primary Power
- 1.7.2 Transmit Power Level Options
- 1.7.3 Differential Absolute Delay Equalization (DADE)
- 1.7.4 Trellis Encoding and Time Domain Equalization (TDE)
- 1.7.5 MCS-11 Alarm/Control Interface
- 1.7.6 Foreign Alarm Interface
- 1.7.7 Relay Interface Option
- 1.7.8 Extended Link Monitor Channel
- 1.7.9 Automatic Transmitter Power Control Provisioning Option
- 1.7.10 Service Channels Provisioning Options
- 1.7.11 Mechanical Options
- 1.7.12 Capacity upgrade
- 1.7.13 Bandwidth upgrade
- 1.8 USER SYSTEM INTERFACE (USI)
- 1.9 RADIO CHARACTERISTICS
- 1.10 EXTERNAL INTERFACE REQUIREMENTS
- 1.11 EQUIPMENT LISTING
- Table 1-6 MDR-8000/i/s Common Shelf Assembly
- Table 1-7 Supplied and Optional Equipment
- Table 1-8 I/O Interface Options
- Table 1-9 XMTR Options
- Table 1-10 PA Options
- Table 1-11 RCVR Options
- Table 1-12 Capacity Keys for Transmitter and Receiver Modules
- Table 1-13 LBO Options
- 1.11.1 Diplexer Filter Kits
- 1.11.2 Standard Filter Kits
- 1.11.3 Cable Drop Kit Option
- 1.12 FAN ASSEMBLY
- 1.13 HANDSET KIT
MDR-8000 Series Radios 3DH03220
General Issue 6, July 2002
1-38
Table 1-7 Supplied and Optional Equipment
UNIT/MODULE PART NUMBER REMARKS
AE-37Y-1 Controller: 3DH 03155 AA One Per Shelf
ELMC Option Key 695-5647-018 Required for remote provisioning and
downloading on DS1/E1 radios, and DS3
and OC3 radios without wayside DS1
ELMC Option Key 695-5647-019 Required for status of DS3 and OC3 radios
with wayside DS1 (no remote provisioning
or download capability provided)
ELMC Option Key 695-5647-020 Required for remote provisioning and
downloading of DS3 and OC3 radios with
wayside DS1
CE-16BB-1 Power Supply: 3DH 03164 AA Two included in Dual T/R assembly kit.
Fuse 264-0928-130 4 ea. 15A fast-blow fuses. (Two opera-
tional and two spares)
DX-35( ) I/O Interface: Capacity and Application
Dependent
Refer to Table 1-8
Two included in Dual T/R assembly kit.
UD-35( ) Transmitter: Application and Frequency
Dependent
Refer to Table 1-9
Two required for hot-standby
UM-62AX Crystal Oscillator Subboard 3DH 04123 AX
Frequency Dependent
The crystal oscillator subboard and crystal
part numbers define this unit. The crystal is
soldered to the oscillator subboard and fac-
tory tuned to the customers requirements.
See drawing 3DH 03177 0000 BJZZA in
the Diagrams Section.
Capacity Key Modulation and Capacity
Dependent
Refer toTable 1-12.
UD-51( ) Power Amplifier Frequency and Output
Power Dependent.
Refer to Table 1-10.
Optional. Two required for hot-standby (if
equipped)
Cooling Fan Assembly Configuration Dependent Assembly with fans always required for PAs
with +27 or +29 (10/11 GHz), +28 dBm
(8 GHz) and +31 dBm (6 GHz) output
power. Assembly with fans and heat deflec-
tor are always required between radios in
a rack with multiple shelf stacking (regard-
less of PA output power).
Fan Assembly Without Lap Top Tray 967-0500-001
Fan Assembly With Lap Top Tray 967-0500-002