User's Manual

3-15
3.9.2
Wayside DS1 Repeater
Recommended connectorized cable assembly – PN 695-4125-051 (26 AWG 5 pair shielded,
jacketed cable with 9-pin D-type connector on each end). See Figure 3-9 for Wayside DS1
repeater interconnect.
Figure 3-9 Wayside DS1 Repeater Interconnect
3.10
DS3 REPEATER (J401 ON ONE SHELF TO J401 ON SECOND SHELF)
The DS3 repeater cable carries clocks, data, and overhead for two
directions. It does not carry DS3 or wayside DS1 traffic. DS3 and way-
side DS1 cables must be run separately. If the 401 cable is not used, the
embedded data in the overhead must be cabled individually. In this
case, individual cables must be run for MCS-11, audio, RS-232, and
ELMC.
Recommended connectorized cable assembly – PN 695-7836-001/005 (25 pair shielded cable
with 50 pin Amp connectors) (SCSI). See Figure 3-10 for shelf connector location and pinout.
Refer to Interconnect section on attached CD for mating cable wiring and color code.
Use repeater cables for cabling repeater shelf 1 to repeater shelf 2 (east-
bound/westbound data/clock)
SHELF 1
OUTPUT
INPUT
LMW-7071-sm
7/24/02
OUTPUT
INPUT
SHELF 2
J201
J202 J202
J201
Note
Note