User's Manual

5-46 This page intentionally left blank.
STEP PROCEDURE, CONTINUED
INSTALL
The PA to heatsink mounting is critical. The three screws securing the
PA to the heat sink must be tightened to 19 in-lbs using a torque
wrench and not over/under-tightened. Improper mounting will
cause over-heating and alarm and shut off power to the PA. This will
result in loss of traffic on unprotected systems. On protected sys-
tems, a switch to the off-line PA will occur.
5 Install PA in shelf. See Figure 5-21.
6 Perform PA Checks and Adjustment procedure. Refer to Appendix E.
7 Was XMTR locked on line (step 2).
If yes, go to step 8.
If no, go to step 9.
8 On AE-37( ) Controller, toggle OVRD switch to disable override (unlocks
on-line XMTR and restores automatic switching functions).
9 STOP. This procedure is complete.
WARNING
Possibility of
Damage
to Equipment