User's Manual

5-58
Figure 5 - 21 XMTR Output Level Calibration (Sheet 3 of 5)
MDR-6061
09/08/05
Back Finish
Abort Back NextAbort Back Next
Save the calibrated values. Click next Storing calibration data, please wait...
Successfully stored calibration data
Click Finish.
Calibration is
complete.
Click Next. Click Next.
i
j
k
Disconnect power meter and sensor
from RF OUT connector.
l
Reconnect cable to RF OUT
connector.
m
Observe RF MON label on XMTR
front panel. On label, is the measured
READ level in dBm or Vdc?
n
If labeled READ X.X dBm, go to step o.
If labeled READ X.X Vdc, go to step s.
Note
Ensure ATPC is disabled.