User's Manual

4-9
Screen for OC3 radio is shown. DS1/E1, DS3, SNMP, and ETH radio
configuration is similar.
Figure 4 - 5 DS1/E1, DS3, OC3/STM-1, ETH Radio Configuration Provisioning (Sheet 1 of 2)
Note
ATPC Disable NO PA
RADIO CONFIG:
Hot-Standby Tx Hot-Standby Rx TERMINAL
10-11 GHz
SYSTEM ALARM
Major/Minor Relays ON/NO Station Alarm 13-16
Degrade Enable
RSL Alarm Enable
RSL-Sw Enable
Eye BER=1x10
-6
RCV SWITCHING:
RADIO TYPE:
MDR-8000 OC3 OC-3 128 TCM
OPTIONS:
Stat/Prov/WaySideOption Key:
SYSTEM ID:
R112
Disable
RADIO LINK ID:ELMC:
Relay Card Present
Displays modulation scheme.
Not provisionable.
Displays radio type.
Not provisionable.
MDR-1030
09/02/04
Displays number of lines available as determined
by
capacity key. Changing number of lines requires
changing
capacity key.
Select DISABLE or double click to enable.
(00 displays). Enter 2-digit number between 00
and 99 as identification for radio RCV/XMT pair.
Use for frequency coordination in congested
areas that have nearby transmitters at same
frequency with same modulation. ID must be
same at both ends of Hop. If RCV ID does not
match ID received from far-end XMTR, a USI
alarm and rack alarm are generated.
Select RSL-Sw Enable to enable automatic
receiver switching based on
RSL. When enabled,
receiver switches if:
1. On-LINE RCV RSL is below RCV AGC
threshold, and
2. Off-LINE RCV RSL is abobe RCV AGC
threshold.
Select RSL-Sw Disable to disable automatic
receiver switching.
Select Major/Minor to trigger major alarm on any
alarm on ON-LINE side and minor alarm on any alarm
on OFF-LINE side. Select Visual/Audible to trigger
rack alarm on any alarm on ON-LINE side.
Select Station Alarm 13-16 to enable Station Alarm
13-16 inputs to relay INFTC. When external TBOS is
wired to radio, select TBOS Display 1-8 to enable
TBOS drivers on controller and select a TBOS display
(1-8) to view.
Select approximate error rate at which eye closure alarm
activates and switching occurs:
EYE BER=1X10
-5
, 1X10
-6
,
1X10
-7
, 1X10
-8
or select
Eye BER Disable
to activate
alarms at approximately 1x10
-6
without receivers switching.
Select A&B PA Present if shelf is equipped with A&B
PAs, or A OR B PA ONLY if shelf is equipped with only
one PA, or NO PA if shelf is not equipped with PA.
Unequipped PA alarms are disabled.
Select Relays ON/NO (normally open-high impedance)
or Relays ON/NC (normally closed-ground) on alarm for
alarms/status outputs, or Relays OFF. Refer to relay
interface in Theory section for deatils.
Displays ELMC option key type installed on controller. STAT
(STATUS)/PROV (remote provisioning)/wayside (with wayside
DS1 monitoring). Not provisionable. Changing display
requires changing option key.
Select TERMINAL, REPEATER, RING TERMINAL
or
RING REPEATER from a dropdown list. Select
REPEATER if traffic and service channel (four rails
of X/Y data) are being transported between J314 of
both shelves.
Enable or disable automatic power
control (ATPC) function. Select ATPC
Disable, ATPC Enabled,
or
ATPC
with Timeout
from dropdown list.
See Sheet 2 of 3 for details.
Backspace to delete current address and
enter 5-digit remote rack address. See
Figure 6-11 for details.