MCS-11 Operation
An Operational Support System (OSS) provides a means to remotely monitor and control
an MDR-8000 radio via an MCS-11 Monitor and Control System polling master. A Remote
Station Summary (RSS), a Remote Detail Scanner (RDS), a Remote Analog Scanner (RAS),
and a Remote Control Decoder (RCD) are available at the polling master for each radio
network element. The remote station OSS addresses are programmed during radio provi-
sioning using the USI laptop computer. (Refer to radio provisioning in the Initial Turn-Up
section.) Refer to Appendix A at the end of this instruction book for MCS-11 details, includ-
ing alarm/status mapping and connector information.
File
Controls -- MDR-8000 DS3
View Setup Options
Alarm Status Performance Station Alarm User Control ProvisioningAnalog Monitor
F4 F5 F6 F7 F8 F9
LOCAL CONTROLS
Communicating*
ELMC Address:
Description:
SILVERTON
A Transmitter On Line
B Transmitter On Line
A Receiver On Line
B Receiver On Line
A I/O On Line
B I/O On Line
A ATPC HIGH Power Lock
B ATPC HIGH Power Lock
A ATPC LOW Power Lock
B ATPC LOW Power Lock
J7915
IN-SERVICE
A I/O LOOPBACK
Line 1 loopback
Line 2 loopback
Line 3 loopback
B I/O LOOPBACK
Control #1
Control #2
Control #3
Control #4
Control #5
Control #6
SYSTEM LOOP-BACK
DS1 LINE LOOP-BACK RCV to XMT
USER CONTROLS
Thursday, November 30, 2000 1:44:19 PM USI Version R1.02 Controller Version R1.02
LMW-5077-sm
08/15/02
2. SELECT I/O INTERFACE MODULE TO PUT IN-SERVICE.
1. OPEN USI CONTROLS SCREEN.
3. SELECT YES ON CONFIRMATION MESSAGE
TO ENABLE FUNCTION.
4. VERIFY GREEN IN-SERVICE STATUS CIRCLE DISPLAYS.