Table 3-14 Alarm/Status Connector J305 Mating Cable Wiring and Pinout
ALM/STATUS/CONTROL
PIN PR
WIRE
COLOR
REMARKS
A XMT ALM OUT
01 1 WHT/BLU
ALARM OUTPUT FROM RELAY INTFC
NOT USED*
26 BLU/WHT
N/A
A RCV ALM OUT
02 2 WHT/ORN
ALARM OUTPUT FROM RELAY INTFC
NOT USED*
27 ORN/WHT
N/A
CONTROLLER FAIL ALM OUT
03 3 WHT/GRN
ALARM OUTPUT FROM RELAY INTFC
SWITCH I/O OUT
28 GRN/WHT
CONTROL OUTPUT FROM RELAY INTFC
SWITCH XMTR OUT
04 4 WHT/BRN
CONTROL OUTPUT FROM RELAY INTFC
SWITCH RCVR OUT
29 BRN/WHT
CONTROL OUTPUT FROM RELAY INTFC
A XMT IN SVCE OUT
05 5 WHT/SLT
STATUS OUTPUT FROM RELAY INTFC
NOT USED*
30 SLT/WHT
N/A
A RCV IN SVCE OUT
06 6 RED/BLU
STATUS OUTPUT FROM RELAY INTFC
NOT USED*
31 BLU/RED
N/A
A I/O IN SVCE OUT
07 7 RED/ORN
STATUS OUTPUT FROM RELAY INTFC
NOT USED*
32 ORN/RED
N/A
PWR SUPPLY ALM OUT
08 8 RED/GRN
ALARM OUTPUT FROM RELAY INTFC
NOT USED*
33 GRN/RED
N/A
STATION ALM 9 IN
09 9 RED/BRN RELAY INPUT FROM CUSTOMER
EQUIPMENT
STATION ALM 1 IN
34 BRN/RED
RELAY INPUT FROM CUSTOMER
EQUIPMENT
STATION ALM 10 IN
10 10 RED/SLT
RELAY INPUT FROM CUSTOMER
EQUIPMENT
STATION ALM 2 IN
35 SLT/RED
RELAY INPUT FROM CUSTOMER
EQUIPMENT
STATION ALM 11 IN
11 11 BLK/BLU
RELAY INPUT FROM CUSTOMER
EQUIPMENT
STATION ALM 3 IN
36 BLU/BLK
RELAY INPUT FROM CUSTOMER
EQUIPMENT
STATION ALM 12 IN
12 12 BLK/ORN
RELAY INPUT FROM CUSTOMER
EQUIPMENT
STATION ALM 4 IN
37 ORN/BLK
RELAY INPUT FROM CUSTOMER
EQUIPMENT
TBOS XMT- DATA IN OR
STATION ALM 13 IN
13 13 BLK/GRN
SERIAL DATA INPUT TO RADIO CON-
TROLLER OR INPUT FROM CUSTOMER
EQUIPMENT TO RELAY INTFC CARD
(PROVISIONABLE)
STATION ALM 5 IN
38 13 GRN/BLK
INPUT FROM CUSTOMER EQUIPMENT
TBOS XMT+ DATA IN OR
STATION ALM 14 IN
14 14 BLK/BRN
SERIAL DATA INPUT TO RADIO CON-
TROLLER OR INPUT FROM CUSTOMER
EQUIPMENT TO RELAY INTFC CARD
(PROVISIONABLE)
STATION ALM 6 IN
39 BRN/BLK
INPUT FROM CUSTOMER EQUIPMENT