User's Manual

Indicators, connectors, and control
9500 MPR Product Information 1093
Table 46.2 MPT-HLC transceiver front panel indicator details
INDICATOR STATUS DEFINITION
Status (S) Off Card not powered
Green Blinking FPGA Downloading, or SW Booting. (Different blink rates
identify each step of the startup process.)
Green In Service, Normal Operation, and Properly Provisioned. EPS
or RPS currently In-Service/Active.
Yellow Card Properly Equipped and Provisioned in 1+1, currently in
Standby.
Green/Red
Blinking
Card Properly Equipped and Provisioned, Rx signal fault, EPS
and RPS in Standby.
Yellow/Red
Blinking
Card Properly Equipped and Provisioned, RX signal Fault, EPS
and RPS currently in Standby. Traffic may be affected.
Red HW Card Fail
Power supply failure (Autotest failure)
FPGA failures
LO alarms
Modem Tx sync alarm
PA switch active
Diversity board card fail (only in combiner mode)
RF switch fail (only for the spare MPT-HLC in HSB
configuration)
In a PA critical temperature condition, the LED remains
green.
Red Blinking MAP Communication Time-out: Communication between the
MPT-HLC Transceiver and the EAS cards is lost. This occurs in
split-mount configuration only.
Power Emission Off MPT-HLC Transceiver is not emitting power, according to the
known configuration, for example, Hot Standby.
Green MPT-HLC Transceiver is emitting power as expected
according to the known configuration.
Yellow MPT-HLC Transceiver is not emitting power due to an
operator command, including manual PA PSU switch or Tx
mute.
Red MPT-HLC Transceiver is abnormally emitting power, in
contrast with the known configuration (for example, when Tx
power alarm is raised during normal operative mode)
SFP interface LEDs
DRAFT